1 -
From the
Devices configuration window, select the
button.
The Miscellaneous
section is hidden in the case of using the KT-400 system because the items
are already defined in the Gateway/KT-400 events.
2 - Select a Site filter from the first drop-down list.
3 - select the Gateway.
4 - From the
drop-down list, select the connection where the controller is located.
5 - From the
drop-down
list, select the output you want to define. Once selected, the language
section is enabled. You may rename the selected output.
6 -
From the General tab, specify
the
for
the output device (default is
Normal
):
•
: The
output is switched to ground when it is activated.
•
: The
output is an open circuit (not grounded) when it is activated.
7 -
In the
section, select which door will affect the output you are configuring:
•
: Only
the first door port will follow the state programmed for these events.
•
: Only
the second door port will follow the state programmed for these events.
This option
is not available with KT-100 and KTES.
8 -
Set the
.
It defines the activation time in seconds during which the output remains
active when it is programmed for a temporary activation. An e will leave
the output activated indefinitely, regardless of the activation type.
Values range from 1 sec to 4 min:15 secs. Default is 5 secs.
This option
is not available when you are using the KT-400 or the KTES.
If
you
are
using the Video Integration feature, EntraPass enables you to assign all
system components into a video view, the same way you assign them to a
system interactive floor plan (graphic). To do this, you simply select
the video view where you want the system component (Workstation, site,
gateway, controller, etc.) to appear.